In the setting of rapidly improving/worsening renal function, calculations of eGFR are inaccurate, and dosing should be based on estimated renal function instead.
If worsening renal function, actual GFR is likely lower than calculated.
If improving renal function, actual GFR is likely higher than calculated eGFR.
Not On Dialysis
300mg PO daily
400mg PO daily
Intermittent Dialysis
200mg PO daily
Continuous Dialysis
200mg PO daily